Staying in compliance with Stage II DBP testing can be a challenge for many small systems. Moreover, when preventing DBP formation becomes a pressing need, it is easy to get overwhelmed by the range and cost of options out there, especially if you are trying to keep up with new technologies. Then there is the fact that solutions to DBP problems often involve several different actions or multiple steps, giving the situation an extra level of challenge.

However, before planning a remediation strategy it might be valuable to initiate a DBP profile study - testing from the source water through the treatment process, and continuing into the distribution system. Why? Because, as Justin Spears in a recent H2Outlook (Kentucky Water & Wastewater Operator's Association) article found out, sometimes the problem isn't where you think it is!

According to his article, he was all set to add a mixer to his storage tank when results from his DBP profile study showed that most of his DBPs were forming in the plant's clearwell. His problem was at the treatment plant, not in the tank! In the end, Justin solved his DBP problem quickly by using chlorine dioxide, made on site by mixing chlorine gas, which he had already in place, with sodium chlorite. However, every treatment plant and source water is different, and what worked for him might not be the best for you.

Interested in finding out more about options for DBP control? Check out this video or this website or this manual. In addition, you can choose Disinfection and Disinfection By-Products as a category in WaterOperator's document or event database to find all sorts of resources.